{"product_id":"specification-support","title":"Specification Support","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDeveloping an appropriate specification for a traditional building, retrofit project or low-energy construction can be complex. Materials must be considered as part of a complete building system rather than selected in isolation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRoundtower’s \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSpecification Support Service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supports architects, designers, contractors and homeowners in developing practical floor, wall and roof build-ups using compatible, vapour-open and moisture-conscious materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur team can assist from the early design stage through to the preparation of detailed material build-ups, product recommendations and supporting thermal or hygrothermal analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHow We Can Help\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe provide specification assistance for a wide range of new-build, renovation and conservation projects, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eInternal wall insulation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExternal wall insulation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInsulating lime plaster specifications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTraditional lime render and plaster systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSolid stone and brick wall upgrades\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLimecrete floor build-ups\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBreathable floor insulation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTimber-frame wall and roof assemblies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWood-fibre insulation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalcium silicate insulation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVapour control and airtightness layers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoof insulation and ventilation strategies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMineral paint and breathable finishing systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRepair mortars, renders and associated conservation materials\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur recommendations consider the complete build-up, including the existing substrate, exposure conditions, insulation, airtightness, vapour control, finishes and junction details.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSupport for Architects and Designers\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe regularly assist architects and building designers with the development of project-specific specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis may include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eReviewing proposed wall, floor or roof constructions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRecommending compatible materials and systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePreparing outline material specifications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdvising on appropriate insulation thicknesses\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReviewing vapour-control and airtightness strategies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIdentifying potential moisture risks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProviding product technical data\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAssisting with U-value targets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdvising on detailing at reveals, floors, roofs and junctions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupporting tender documentation and contractor queries\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur objective is to provide clear and practical guidance that can be incorporated into the project design and developed by the appointed design team.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSupport for Traditional and Historic Buildings\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTraditional solid-wall buildings require a different approach from modern cavity construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA specification that performs well in a modern building may not be suitable for older stone or brick walls, particularly where the structure relies on vapour-permeable materials and capillary drying.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen developing a specification for a traditional building, we consider factors such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eExisting wall construction and thickness\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStone, brick or block type\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMortar and plaster condition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMoisture sources\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDriving-rain exposure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGround levels and drainage\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal heating and ventilation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSalt contamination\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaterial vapour permeability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCapillary moisture transport\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDrying potential\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThermal bridging and surface-temperature risk\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis helps reduce the likelihood of selecting materials that could trap moisture or place unnecessary stress on the existing building fabric.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWUFI Hygrothermal Analysis\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhere a more detailed assessment is required, Roundtower can provide \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWUFI hygrothermal analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWUFI modelling assesses the movement of heat and moisture through a building element over time. Unlike a simple steady-state condensation calculation, it can consider changing internal and external conditions, rainfall, solar radiation, moisture storage, vapour diffusion and liquid moisture transport.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWUFI analysis may be particularly useful for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eInternal insulation on solid masonry walls\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExposed or moisture-sensitive elevations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHistoric stone and brick construction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComplex roof and timber-frame assemblies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVapour-open insulation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProjects where condensation or moisture accumulation is a concern\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComparing alternative insulation or finishing systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAssessing drying potential following retrofit works\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe analysis can help identify whether moisture is likely to accumulate within an assembly and whether the proposed construction is expected to reach a stable long-term condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWUFI modelling should be treated as a design-support tool rather than a guarantee of building performance. The accuracy of the results depends on the quality of the material data, climate assumptions, boundary conditions and information available about the existing building.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eU-Value Modelling\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe can also calculate and compare the estimated thermal performance of proposed floor, wall and roof build-ups.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eU-value modelling service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e can help clients:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eCompare different insulation products\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAssess alternative insulation thicknesses\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEstimate improvements over the existing construction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupport compliance and design decisions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBalance thermal performance against available space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompare vapour-open retrofit options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUnderstand the effect of thermal conductivity and material thickness\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhere appropriate, we can model several options so the client or design team can compare thermal performance, build-up thickness and material suitability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eU-value calculations assess heat loss under standardised conditions. They do not, on their own, assess moisture movement, thermal bridging, workmanship, air leakage or real-world building operation. For moisture-sensitive constructions, a U-value calculation may therefore need to be supported by additional hygrothermal assessment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFloor Specification Assistance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe can assist with the development of breathable and insulated floor build-ups for traditional and modern buildings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis may include advice on:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eLimecrete floors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFoamed-glass aggregate insulation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRadon protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeotextile and separation layers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUnderfloor heating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFloor finishes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eJunctions with solid masonry walls\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMoisture movement through floors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinished floor levels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoad and compaction requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEach floor specification must be considered in relation to the building, ground conditions, structural requirements and proposed use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWall Specification Assistance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur wall specification service covers both thermal upgrades and traditional repair systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTypical projects include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eInternal wall insulation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExternal wall insulation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInsulating lime plaster\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWood-fibre insulation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalcium silicate insulation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLime plaster and render\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRepointing and masonry repair\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVapour-control layers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAirtightness systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBreathable paints and finishes\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe can help assess the advantages and limitations of different systems and identify which approach is most appropriate for the wall construction and project objectives.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRoof Specification Assistance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRoof build-ups require careful consideration of insulation, airtightness, vapour control, ventilation and moisture safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe can provide guidance on:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eInsulation between, above or below rafters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWood-fibre roof insulation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlexible insulation between timbers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVapour-control layers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntelligent vapour-control membranes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAirtightness detailing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBreather membranes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVentilated roof voids\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eService cavities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal finishes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoof-to-wall junctions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe correct solution will depend on whether the roof is pitched or flat, ventilated or unventilated, and whether the building is new, existing or traditionally constructed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eA Project-Specific Approach\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere is no single specification that is suitable for every building.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur advice is based on the information available for the individual project, which may include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eDrawings and construction details\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSite photographs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExisting wall or floor build-ups\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaterial data sheets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSurvey information\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMoisture readings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProject location and exposure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProposed heating and ventilation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePlanning or conservation requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequired thermal performance\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhere important information is unavailable, we will identify the assumptions being made and may recommend further investigation before a final specification is adopted.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho Is This Service For?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur Specification Assistance Service is available to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eArchitects\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eArchitectural technologists\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEngineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConservation professionals\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilding designers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnergy consultants\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContractors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-builders\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHomeowners\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProperty developers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePublic bodies and heritage organisations\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe can assist with both small domestic projects and more complex commercial, conservation or institutional buildings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDiscuss Your Project With Roundtower\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf you are developing a floor, wall or roof specification, contact the Roundtower technical team with your drawings, photographs and available project information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe can review the proposed construction, recommend appropriate materials and advise whether U-value modelling or WUFI hygrothermal analysis would be beneficial.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eContact Roundtower today for practical specification assistance for breathable, energy-efficient and traditionally constructed buildings.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Roundtower Lime Ireland","offers":[{"title":"Default Title","offer_id":46924253069485,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0648\/7297\/2461\/files\/Specification_Support_Service.png?v=1785160381","url":"https:\/\/www.roundtowerlime.com\/products\/specification-support","provider":"Roundtower Lime Ireland","version":"1.0","type":"link"}